Heating Load & Radiator Sizing Calculator (Watts & Sections per m²)

Calculate room heating power in Watts and the number of radiator sections needed based on floor area, climate zone and water ΔT (EN 442).

Required Heating Power1.863 W
Radiator Sections Needed15 sections
Thermal Output (kcal/h)1.602 kcal/h
Specific Heat Load103.5 W/m²

Radiator Thermal Output & Delta-T (ΔT) Correction Formula (EN 442)

Thermal Standard (EN 442 & ASHRAE): Radiator heat output drops non-linearly with lower water temperatures according to the exponent n ≈ 1.30.

ΔT = ((T_supply + T_return) / 2) - T_room
Actual Heat Output: P = P_rated(ΔT50) × (ΔT / 50) ^ 1.3

Heating Demand Reference by Climate Zone (W/m²)

Climate ZoneReference Climate TypeWell Insulated HomeAverage / Older Insulation
Zona A / BMild Coastal / Mediterranean Climate65 W/m²80 W/m²
Zona CTemperate Maritime / Oceanic Climate75 W/m²95 W/m²
Zona DCold Continental / Inland Plateau90 W/m²110 W/m²
Zona ESevere Mountain / High Altitude (>800m)105 W/m²130 W/m²

Frequently Asked Technical Questions (FAQ)

How many Watts per m² and radiator sections are needed?

Depending on insulation and climate zone, rooms require 65 to 110 W/m². At standard boiler ΔT 50°C, a 60cm aluminum radiator section outputs ~125 W.

How does water temperature (ΔT) affect radiator output under EN 442?

Under EN 442, heat output scales with (ΔT / 50)^1.3. Running a low-temperature heat pump at ΔT 30°C reduces radiator output by roughly 48%.