Solar & Off-Grid Battery Bank Calculator (Ah & kWh Sizing)

Calculate required battery bank capacity in Amp-hours (Ah) and kWh from daily consumption, system voltage (12V, 24V, 48V), autonomy days and LiFePO4/AGM DoD.

Min Nominal Capacity294 Ah
Total Bank Energy3.53 kWh
Required Usable Energy3.00 kWh
Recommended Bank Size300 Ah

Battery Bank Energy & Amp-Hour Sizing Formula

Engineering Standard (IEEE 485 / IEC 61427): Battery sizing must account for inverter conversion efficiency (~90%) and maximum allowable Depth of Discharge (DoD: 85% for LiFePO4, 50% for AGM).

Total Capacity (Ah) = (Daily Consumption Wh × Autonomy Days) / (Voltage × DoD × η_inverter)

Technical Comparison: Lithium LiFePO4 vs. AGM / Gel Lead-Acid

Technical ParameterLithium Iron Phosphate (LiFePO4)Lead-Acid AGM / Gel
Depth of Discharge (DoD)80% - 95% without cycle degradation50% max to prevent plate sulfation
Estimated service life3,500 to 6,000 cycles at 80% DoD400 to 700 cycles at 50% DoD
Weight per 100Ah at 12V11 kg - 13 kg28 kg - 32 kg
Voltage sag under heavy loadFlat discharge curve at 13.2V - 12.8VDrops rapidly below 12.0V (Peukert effect)

Frequently Asked Technical Questions (FAQ)

How do you calculate solar battery bank capacity in Amp-hours (Ah)?

Multiply daily energy use (Wh) by required autonomy days, then divide by (System Voltage × Max Depth of Discharge DoD × Inverter Efficiency).

Why choose LiFePO4 over AGM lead-acid batteries?

LiFePO4 batteries safely allow an 85%–90% Depth of Discharge (DoD) for over 4,000 cycles, whereas AGM batteries must be limited to 50% DoD.