Compare annual heating energy consumption and cost between an air-to-water heat pump (by SCOP) and a natural gas or oil condensing boiler.
Efficiency Standard (EN 14825): A heat pump with SCOP 4.0 delivers 4 kWh of thermal heat per 1 kWh of electricity consumed from the grid.
| Heating Emitter System | Supply Water Temp | Average Real SCOP | Grid Electricity per 10,000 kWh Heat |
|---|---|---|---|
| Underfloor Heating System | 30 °C - 35 °C | 4.3 to 4.8 | 2,220 kWh electricity |
| Fan Coils / Low-Temp Radiators | 40 °C - 45 °C | 3.6 to 4.0 | 2,630 kWh electricity |
| Standard High-Temp Radiators | 55 °C - 60 °C | 2.8 to 3.2 | 3,330 kWh electricity |
Divide your electricity rate per kWh by the seasonal SCOP: at 0.20 €/kWh and SCOP 4.0, each kWh of delivered heat costs just 0.05 €.
Underfloor heating (35°C water) achieves a SCOP of 4.3–4.8, whereas high-temperature radiators (55°C–60°C) reduce SCOP to ~3.0.